H-Sorb ***0 high pressure gas adsorption volumetric
principle analyzer introduction
Gas sorption analysis is important in many fields of materials,
such as energy storage materials, improved catalysts for
petrochemical processing, advanced pharmaceuticals and food
industries. At present, there is tremendous interest in the
development of innovative materials for the transition to renewable
energy. The science of gas sorption has become particularly
critical in the advancement of materials for storing fuel gases
such as hydrogen or natural gas, as well as for sequestration of
greenhouse gases.
The H-Sorb ***0 high pressure gas sorption analyzer adopts the volumetric technique principle which consists of dosing a known amount of gas adsorptive into measurement tubes where lying samples (such as zeolites, carbon nanotubes, rocks, catalysts, activated carbons, molecular sieve, hydrides etc. ) to be analyzed. When samples reach equilibrium with the adsorbate gas (such as hydrogen, methane, carbon dioxide, nitrogen, argon, krypton etc.), detailed and comprehensive final equilibrium pressures will be recorded automated by Gold APP Instruments company dedicated and patented software. These data are used to calculate the quantity of gas adsorbed by samples. This measurement procedure automatically repeated by software under given temperature and pressure intervals until finalized the maximum preselected pressure. Finally, each of the equilibrium points volume adsorbed, equilibrium pressure, absolute pressure etc. data are plotted to produce the isotherm. By using the isotherm data, operators can calculate further more information such as Langmuir fitting isotherm, the adsorption rate curve, PCT (pressure-composition-temperature) or PCI (pressure-composition-isotherm) curve etc.
Pressure-Composition Isotherms (PCI) and Pressure-Composition Temperature (PCT) is one of the most informative sorption measurements. The result is a plot of the equilibrium absorbed gas concentration in the material as a function of pressure and temperature.
Gold APP Instruments high pressure and high temperature gas
sorption analyzer H-Sorb ***0 adopts static volumetric principle to
determine adsorption and desorption isotherms under high pressure
(atmospheric to **0Bar) and high temperature (atmospheric to **0℃)
with a stainless steel VCR manifolds system, fully automated
operation can control system and multi calculation methods, all
these guarantee H-Sorb ***0 to produce a highly repeatibility and
highly precision analysis data.
H-Sorb ***0 high pressure gas adsorption volumetric principle analyzer parameters
1. Analysis Method: static volumetric principle, high
pressure gas sorption principle
2. Versatility: adsorption/desorption isotherms measurement
(atmospheric to **0℃), Gibbs supercritical adsorption
measurement
3. Data Reduction: Langmuir model regression isotherm,
PCT(Pressure-Composition-Temperature) or PCI
(Pressure-Composition-Isotherm) diagram/curve/isotherm measurement,
Langmuir maximum adsorption constant L and adsorption pressure
constant B measurement; Langmuir correction model loading-ratio
correlation regression (LCR) isotherm; Ono-Kondo (OK) lattice model
isotherm regression; adsorptive gas density and vapor-liquid
equilibrium accuracy calculation under different pressures and
temperatures
4. Measuring Ranges: continuous adsorption and desorption
measurement from atmospheric to **0Bar pressure
5. Accuracy: repeatability errors <3%
6. Temperature Range: cryogenic to **0℃, accuracy±0.1℃
7. Sample Ports: two samples analyzing and two degassing,
stainless-steel micro welding sample cells, software integrated
temperature PID adjustment
8. Transducer Accuracy: imported high precision transmitter,
accuracy can reach 0.*5% of F.S. (full-scale), long-duration usage
stability is 0.**5% of F.S.
9. Ultimate Vacuum: 4x***2 Pa (3x***4 Torr), molecular pump
system (1x***6 Pa) is optional
*0. Adsorbate Gas: high purity nitrogen, CO2 or others (Ar,
Kr, H2, CH4 etc.)
*1. Data Acquisition: high-precision and high integration data
acquisition modules, minimal error, strong anti-interference
ability
*2. Specifications: Height *2.*5 inches (*6cm)* Width *0.*7
inches (*3cm)*Depth *3.*2 inches (*0cm); **2 pound (*0kg);
**0V/5A
H-Sorb ***0 high pressure gas adsorption volumetric
principle analyzer features:
1. Control System: imported VCR interface high pressure pneumatic valve can realize auto on-off within **0Bar, sealing performance is top to 1x****0 Pa.m3/s, can be used more than **0 million times; programmable logic controller (PLC) system, high integration and sound anti-interference, improve stability and prolong life
2. Analysis Management: parameters be set by Gold APP
Instruments software, fully automated, achieved unattended
operation at night; H-Sorb mode is available for accurate control
gas charging pressure points, gain ideal data points
3. Manifold System: imported **6L stainless steel thick-walled
manifolds, micro welding sealing can reduce dead space largely;
metal VCR connection is convenient for installation and
uninstallation
4. Safety Measures: H-Sorb asymptotic technology realizes auto gas-charging and degassing, prevents high pressure dangers caused by artificial misoperation, and also minimizes large differential pressures impact to pressure transducer
H-Sorb ***0 high pressure gas adsorption volumetric principle analyzer application
1. Study and research in high temperature and pressure gas
sorption, supercritical gas performance, microporous materials,
hydrogen storage materials, coalbed gas, oil exploration, methane
etc.
2. Catalysts, molecular sieves, active carbon, carbon
nano-tube, fuel cell, hydrocarbon and other materials.