ARI-800B+ Patient Monitor
Next

ARI-800B+ Patient Monitor

FOB Price

Get Latest Price

|

- Minimum Order

Country:

China

Model No:

-

FOB Price:

Get Latest Price

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

-

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

-

Payment Type:

-

Product Group :

-

Contact Now
Free Member

Contact Person Joanna

Economic Development Zone, Hefei, Anhui

Contact Now

Product Specification

Product Description

*5 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
 
1.*3 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
3. SPO2 can testing for 0.1% Weak;
4. RA-LL impedance Respiration;
5. Trend Coexist Display;
6. OxyCRG Dynamic View Display;
7. Bed to Bed view Display;
8. Networking capacity and nurse calling system;
9. Options of printing, IBP, VGA and EtCO2;
*0. UP to 4 hours working capacity of built-in rechargeable battery;
*1.*5" high resolution color TFT LCD display;
*2. Large volume of tabular and graphic trends information storage and easy to recall;
*3. Anti-ESU, anti- defibrillator;
*4. Capture dynamic waveforms.
 
Technical specification:
 
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: 2.5mm/mV, 5.0mm/mV, *0mm/mV, *0mm/mV, auto
 
HR and Alarm
Range
Adult: *5 ~ **0 bpm
Neo/Ped: *5 ~ **0 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > **0 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > **5 dB
Operation: > **5 dB
Diagnosis: > *5 dB
Electrode offset potential: ±**0mV
Leakage Current: < *0uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth  
Surgery: 1 ~ *5 Hz
Monitor: 0.5 ~ *5 Hz
Diagnostic: 0.*5 ~ **0 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5% 
ST Segment Monitoring Range: Measure and Alarm *2.0 ~ *2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
 
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ **0 rpm
Neo/Ped: 0 ~ **0 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: *0 ~ *0 S
 
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, *0, *5, *0, *0, *0,
**0, **0, **0,**0 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: *0 ~ **0 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
  Adult Mode
SYS: *0 ~ **0 mmHg
DIA: *0 ~ **5 mmHg
MEAN: *0 ~ **5 mmHg
  Pediatric Mode
SYS: *0 ~ **0 mmHg
DIA: *0 ~ **0 mmHg
  MEAN: *0 ~ **5 mmHg
Neonatal Mode
SYS: *0 ~ **5 mmHg
DIA: *0 ~ **0 mmHg
MEAN: *0 ~ **0 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: **7±3 mmHg
Pediatric Mode: **0±3 mmHg
Neonatal Mode: **7±3 mmHg
 
SpO2
Measuring Range: 0 ~ **0 %
Alarm Range: 0 ~ **0 %
Resolution: 1 %
Accuracy: *0% ~ **0% ±2 %
          0% ~ *9% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: *0 Sec.
Pulse Rate
Measuring and Alarm Range: *0~**0bpm
Resolution: 1bpm
Accuracy: ±2bpm
 
TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ *0 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant: <*0 Sec.
 
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ **0 mmHg
PA: *6 ~ **0 mmHg
CVP/RAP/LAP/ICP: **0 ~ *0 mmHg
P1/P2: **0 ~ **0 mmHg
Press Sensor
Sensitivity: 5uV/V/mmHg
Impedance: *******0Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
 
Standard Packing List:            
*-lead ECG cable (including RESP)
Adult finger SpO2 sensor          
Adult NIBP cuff                   
NIBP extension tube               
TEMP sensor                       
AC power adaptor                  
ECG electrodes                    
Operation instruction             
Selectable Accessory:             
Child finger SPO2 sensor          
Child NIBP cuff                   
Neonate NIBP cuff  
*5 inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
 
1.*3 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
3. SPO2 can testing for 0.1% Weak;
4. RA-LL impedance Respiration;
5. Trend Coexist Display;
6. OxyCRG Dynamic View Display;
7. Bed to Bed view Display;
8. Networking capacity and nurse calling system;
9. Options of printing, IBP, VGA and EtCO2;
*0. UP to 4 hours working capacity of built-in rechargeable battery;
*1.*5" high resolution color TFT LCD display;
*2. Large volume of tabular and graphic trends information storage and easy to recall;
*3. Anti-ESU, anti- defibrillator;
*4. Capture dynamic waveforms.
 
Technical specification:
 
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1ch
Gain: 2.5mm/mV, 5.0mm/mV, *0mm/mV, *0mm/mV, auto
 
HR and Alarm
Range
Adult: *5 ~ **0 bpm
Neo/Ped: *5 ~ **0 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > **0 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > **5 dB
Operation: > **5 dB
Diagnosis: > *5 dB
Electrode offset potential: ±**0mV
Leakage Current: < *0uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth  
Surgery: 1 ~ *5 Hz
Monitor: 0.5 ~ *5 Hz
Diagnostic: 0.*5 ~ **0 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5% 
ST Segment Monitoring Range: Measure and Alarm *2.0 ~ *2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
 
RESPIRATION
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ **0 rpm
Neo/Ped: 0 ~ **0 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apean Alarm: *0 ~ *0 S
 
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, *0, *5, *0, *0, *0,
**0, **0, **0,**0 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: *0 ~ **0 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
  Adult Mode
SYS: *0 ~ **0 mmHg
DIA: *0 ~ **5 mmHg
MEAN: *0 ~ **5 mmHg
  Pediatric Mode
SYS: *0 ~ **0 mmHg
DIA: *0 ~ **0 mmHg
  MEAN: *0 ~ **5 mmHg
Neonatal Mode
SYS: *0 ~ **5 mmHg
DIA: *0 ~ **0 mmHg
MEAN: *0 ~ **0 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: **7±3 mmHg
Pediatric Mode: **0±3 mmHg
Neonatal Mode: **7±3 mmHg
 
SpO2
Measuring Range: 0 ~ **0 %
Alarm Range: 0 ~ **0 %
Resolution: 1 %
Accuracy: *0% ~ **0% ±2 %
          0% ~ *9% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: *0 Sec.
Pulse Rate
Measuring and Alarm Range: *0~**0bpm
Resolution: 1bpm
Accuracy: ±2bpm
 
TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ *0 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant: <*0 Sec.
 
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ **0 mmHg
PA: *6 ~ **0 mmHg
CVP/RAP/LAP/ICP: **0 ~ *0 mmHg
P1/P2: **0 ~ **0 mmHg
Press Sensor
Sensitivity: 5uV/V/mmHg
Impedance: *******0Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
 
Standard Packing List:            
*-lead ECG cable (including RESP)
Adult finger SpO2 sensor          
Adult NIBP cuff                   
NIBP extension tube               
TEMP sensor                       
AC power adaptor                  
ECG electrodes                    
Operation instruction             
Selectable Accessory:             
Child finger SPO2 sensor          
Child NIBP cuff                   
Neonate NIBP cuff                 
              

Country: China
Model No: -
FOB Price: Get Latest Price
Place of Origin: -
Price for Minimum Order: -
Minimum Order Quantity: -
Packaging Detail: -
Delivery Time: -
Supplying Ability: -
Payment Type: -
Product Group : -

Send a direct inquiry to this supplier

To:

Joanna < ARI Medical Equipment Co., Ltd >

I want to know: